Lab results on the batch record: one data, two entries

A lab result is recorded once, in the lab data series; the batch record reads it by batch number and does not copy it. So you can add a sample on the batch record or on the Data series page: the same row shows in both places, and a correction appears in both at once. A closed batch can still receive results.

  • Permission: series:record (Data series: record). For corrections series:correct.
  • The batch’s template has lab points and parameters (Batch template). The expected point and parameter pairs give the lab status.
  1. Record on the batch record. In the Lab part of the batch sheet choose New lab sample. Give the sample point (from the template’s points), the sampling time and the values of the parameters; the free text Other can be filled in too. Record sample. It goes into the same lab series as a sample recorded on the Data series page.
  2. Record on the Data series page. On the lab series the recording row lets you pick the batch from a list (open and recently closed batches) and the sample point from the template. A number that has no batch is flagged but not lost: if that batch is opened later, the row attaches to it.
  3. Limit and status. The limit lives in the template, per sample point and parameter. The Lab: OK / Deviation / Pending / No lab badge in the batch header shows the overall status. While an expected measurement is missing the lab is pending; on a closed batch it reads Missing sample (at least one sample arrived) or No lab data (none did). On the Batches list, hovering, tapping or tabbing to the badge shows why: the out-of-limit pairs (“M-1 · Szárazanyag 19.3 % (limit 13–18)”) and the points without a sample (“No sample: M-2, M-3”), a missing result on a sampled point (“Missing result: M-1 · Water”) and values that cannot be assessed. If every expected result is in but one is not a number next to a limit, the badge reads Not assessable; on a voided batch Not assessed; on mobile the reason is on the card. Which points are expected is a template setting. A value outside its limit is marked below limit / above limit. A point or parameter that is not in the template can be recorded, but does not count towards the lab status (“not a template point”).
  4. A step that comes from the lab. A Comes from the lab step shows the latest effective result (Lab result). If you override it, the manual value stands beside the lab value, both are shown; the status is the worse of the two, so a deviation is never silently turned into “OK”.
  5. Correct. A lab row is corrected with a reason; on a closed batch correcting the manual value needs series:correct.

The Lab part of the batch sheet shows the result, the limit and the status per point and parameter, the number of samples is visible, and the same row is on the Data series page. The batch analysis counts a late result too.

What you see Why What to do
“No lab sample for this batch yet” No sample has been recorded for this number. Add one, or check the batch number.
“The lab series doesn’t exist yet: publishing the template creates it” The template is still a draft. Publish the template.
“n samples are at a point that isn’t in the template” The sample’s point is not a template point. Record it on a template point, or add the point in a new template version.
A sample is not attached to a batch The batch number is missing or unknown. The analysis counts it as a gap, “Samples without a batch”; fix the number.