Log an event in the diary
If something during your shift needs to leave a trace — a fault, an HSE event, a material release, a process deviation — you log it under the Events element of the diary. A logged event is closed together with the diary, goes into the diary PDF, and can later be filtered and exported from the Events tab under Reports.
Before you start
Section titled “Before you start”Two conditions must hold, otherwise the add button will not even appear:
- Permission: the “Log event” right — event:create. By default this belongs to the Shift leader; if another role has it in your organisation, your admin configured it that way.
- An open diary: the diary must still be editable. A closed or archived diary can only be viewed; you can no longer add events to it.

- Open the diary the event belongs to and scroll to the Events element.
- Click Add event. The logging form opens. (The same button closes it again — it then reads “Cancel”.)
- Choose the Event type. The list offers your organization’s event types, in your admin’s order and under their names. By default these are: HSE · Technical fault · Quality deviation · Maintenance-requiring · Process · Material release · Other information — but your admin may have added custom types or disabled a built-in one (Manage event types and subcategories).
- If the type has subcategories, a Subcategory picker appears (for example Technical fault → Pump). A subcategory is optional: leave it on “— no subcategory —” if none fits. When you change the type the choice is cleared, because every subcategory belongs to one type. If you chose HSE (or another type that asks for a severity), the HSE severity field appears too — it is then required. Its values are: Near miss · Incident · Accident (or “— (non-safety)”). For any other type the field is not shown at all.
- Give a Short title — this becomes the identifiable name of the event in lists and in the report. Be specific: “P-15-03 pump bearing failure”, not “fault”.
- Write the Description: what happened, and what action was taken. This is the field a later investigation will actually read — you are writing it for your future self.
- Fill in the Installation location if it applies (“reactor line 2, P-15-03”).
- Enter the From and — if the event went on — the To time. The date comes from the diary, so here you only give hours and minutes, and only within the shift window. For a one-off event (flaring, for example) “To” can safely stay empty.
- Tick Caused downtime and/or Caused production loss if true. These are filterable in the report — an unticked box means it did not.
- Click Log event.
If it worked
Section titled “If it worked”You get the “Event logged.” confirmation, the form closes, and the event appears immediately in the Events list — with a “Logged by <your name> · <time>” line underneath. That signature is automatic and not editable: it is what makes the trail auditable.
Photos and dictation
Section titled “Photos and dictation”- Photos: if your admin has switched it on, you can attach photos to the event — see Upload a photo in the diary; what changes what in the PDF and the views: Managing photos.
- Dictation: if your admin has switched it on and your browser supports it, a “Dictate” button appears at the text field — see Dictation in the diary.
If you don’t know which site it belongs to
Section titled “If you don’t know which site it belongs to”The Record company-level event button at the header of the Events element records an event without a site — for example when you notice something on the road between two sites. Such an event does not go into the log or the shift PDF: it goes, as “Awaiting classification”, to a classifier who assigns it to a site. Without company-wide scope you won’t see it (nor get an identifier) until it is classified; no photo can be attached. The button is shown only while the log can be edited (not in the read-only archive view). Details: Move an event to another site, and the “Awaiting classification” report.
Common problems
Section titled “Common problems”| What you see | Why | What to do |
|---|---|---|
| “The time is outside the shift window.” | The hour and minute you gave do not fit the diary’s shift window. | Check the hint under the field — it prints the exact window. If the event really happened during another shift, it belongs in that shift’s diary. |
| “Select an event type.” | The type was left empty. | This is the one field you cannot save without — otherwise the event could not be classified in the report. |
| “Give the event a short title (min. 2 characters).” | Empty or one-character title. | Write a meaningful title — it is the only thing visible in the list. |
| “HSE severity is required for an EBK event.” | You chose the HSE type (or another type that asks for a severity) but left the severity empty. | Pick a severity. If the event is not actually safety-related, HSE is probably the wrong type. (The message says “EBK” — that is the Hungarian abbreviation for HSE; it is also shown for a custom type that asks for a severity.) |
| There is no “Subcategory” field | The chosen type has no (active) subcategory. | Nothing to do — a subcategory is optional. If you need one, ask your admin: Manage event types and subcategories. |
| No “Add event” button | Either you do not have the event:create permission, or the diary is no longer editable (closed / archived / view-only). |
If the diary is open, ask your admin for the permission; if it is closed, the event can no longer be added to it. |
What happens to the event afterwards
Section titled “What happens to the event afterwards”- It goes into the diary PDF — into the “Events” block, if your report template includes it; the subcategory (if any) is printed next to the type (Technical fault · Pump).
- It appears under Reports → Events, where all events of the site sit in one table that can be filtered, sorted and exported — this is how you review and export them. Which site’s data you see is decided by your role’s site access.
- It gets an ID, and its fate is tracked in the Reports table. The diary and the PDF show the event’s ID; its status (New → … → Closed) and closing reason show only in the Events table, the side panel and the export — where you can also change the status: Handle events from the table.
- Events do not only come in by hand: if your organisation has switched on field reporting, anyone can report by scanning a QR label, without signing in — such an event enters the diary marked “Field report — unverified reporter”, and you classify it with a supplement. The manual form does not offer the “Field report” type. Details: Field report by QR label.